Most warm-air problems come from a thermostat setting, a clogged filter, a tripped breaker for the outdoor unit or a frozen coil. Low refrigerant always needs a licensed technician.

Short answer: Usually a thermostat setting, a clogged filter, a tripped breaker for the outdoor unit or a frozen coil. Set the thermostat to Cool, check the filter, reset the outdoor breaker once and let any ice thaw. If it still blows warm air, turn it off and call an HVAC technician.
Check the warning signs below first.
Use this guide at your own risk. It’s general information, not professional advice. By using it, you agree to our Terms of Use and Safety Waiver.
Check for danger first
If any of these are present, stop here.
- Gas odor, smoke or fire. Leave immediately. From outside, call emergency services. For a gas odor, also call the gas utility. Leave lights and switches alone.
- Burning smell, scorch marks, a hot outlet or a buzzing panel. Stop and call an electrician. Stay clear of a suspect panel.
- Water near electrical equipment or exposed wiring. Keep away. Never cross water to reach a plug or breaker. Call a qualified electrician.
None of these warning signs? Open the checks
What to check
Have ready. A new air filter in the right size and the location of your breaker panel.
Set the thermostat to Cool with the fan on Auto.
Set it below room temperature. With the fan on ON, it blows air that isn’t cooled between cycles.
Check the air filter.
Replace it if it’s clogged. A dirty filter starves the system of air and can freeze the indoor coil.
Check the outdoor unit’s breaker once.
If the indoor fan runs but the outdoor unit is silent, look for a tripped AC breaker in the panel. Reset it only once. If it trips again, leave it off and call a technician.
Let a frozen coil thaw.
If you see ice on the copper lines or the indoor unit, turn the system off and let it thaw for a few hours before running it again, then call for service.
When to stop. If it keeps blowing warm air, turn the AC off to protect the compressor and call a licensed HVAC technician. Call right away for ice, a second breaker trip, an outdoor unit that won’t run, or any refrigerant concern.
What it costs
- The checks above: free.
- Pro AC repair: $150–$700.
- Common fixes: a new capacitor, $100–$400; a refrigerant recharge, $100–$600 (more if a leak needs repair).
National US ranges from 2025–2026 cost guides: Fixr · This Old House · Thumbtack. Prices in your area may differ.
Common causes
- Thermostat setting. Set to Heat, Fan On or a temperature above the room, the system won’t cool. You can check
- Dirty air filter. A clogged filter chokes the airflow, so less cool air reaches the rooms and the coil can freeze. You can check
- Tripped breaker for the outdoor unit. The fan indoors still runs, but the outdoor unit that does the cooling has no power. You can check
- Frozen indoor coil. Ice on the coil blocks airflow. It usually comes from a dirty filter or low airflow; if it keeps freezing, call a pro. You can check
- Failed capacitor. This part helps the outdoor motors start. It holds a dangerous electrical charge even with the power off. Call a pro
- Low refrigerant from a leak. Refrigerant doesn’t get used up; low refrigerant means a leak that a licensed technician must find and repair. Call a pro
Sources: Carrier · Trane · U.S. Dept. of Energy.
Further reading · Carrier
Still stuck? Get help with your exact problem.
Snap a photo and tell the app what you’ve tried. It walks you through your model, one safe step at a time, and tells you when to call a pro. Your first fix in the app is free.
The app is coming soon. Get one email the day it launches.