Condensate pump not working
Check the power, tank, float and tubing on a condensate pump, and tell when a full pump is why your AC or furnace shut off.

Short answer: A condensate pump usually stops because it lost power, the float is dirty or stuck, or the outlet tubing is kinked or clogged. Its high-water switch can then shut off the AC. Check the power, tank and tubing; if it still won’t pump, call an HVAC technician to replace it.
Check the warning signs below first.
Use this guide at your own risk. It’s general information, not professional advice. By using it, you agree to our Terms of Use and Safety Waiver.
Check for danger first
If any of these are present, stop here.
- Gas odor, smoke or fire. Leave immediately. From outside, call emergency services. For a gas odor, also call the gas utility. Leave lights and switches alone.
- Burning smell, scorch marks, a hot outlet or a buzzing panel. Stop and call an electrician. Stay clear of a suspect panel.
- Water near electrical equipment or exposed wiring. Keep away. Never cross water to reach a plug or breaker. Call a qualified electrician.
None of these warning signs? Open the checks
What to check
Have ready. A flashlight, a towel, dry hands and shoes, and the pump’s brand or manual.
Check the power.
Make sure the pump is plugged in and its breaker is on. If it plugs into a GFCI outlet, press RESET once. Keep your hands dry and don’t stand in water near it.
Look at the tank.
If the tank is full and the pump doesn’t run, the float may be dirty or stuck, and a pump that isn’t level may not switch on. If your manual shows how, unplug it first, then clean the tank and float. Little Giant suggests a 50/50 mix of water and vinegar and warns that chlorine damages the pump.
Check the tubing.
Follow the outlet tubing to where it drains. Straighten any kinks and look for slime or debris blocking it. A blocked outlet makes the tank overflow.
Know the safety switch.
Many pumps have a high-water switch that shuts off the AC when the tank is full. If the AC stopped and the pump is full, that switch is doing its job. Never bypass it or unhook its wires.
When to stop. If the tank is full, the power is on and the float moves freely but the pump won’t run, or it runs but won’t move water, stop and call an HVAC technician. A failed switch or motor means replacing the pump, and there are no user-serviceable parts inside.
What it costs
- The checks above: free.
- Condensate pump replacement: $100–$500.
- Most HVAC companies charge a $75–$150 diagnostic fee, and some apply it to the repair.
National US ranges from 2025–2026 cost guides: Fixr · This Old House. Prices in your area may differ.
Common causes
- No power. An unplugged cord, a tripped breaker or a tripped GFCI stops the pump. You can check
- Kinked or blocked tubing. Water can’t leave the tank, so it overflows or trips the safety switch. You can check
- Dirty or stuck float. Buildup can make the float too heavy to work, so the pump never switches on. Call a pro
- Stuck or plugged check valve. The pump can run but won’t move water out. Call a pro
- Failed switch or motor. Little Giant says a defective switch or motor means the pump must be replaced. Call a pro
Sources: Little Giant · Little Giant manual.