Heat pump running constantly
Tell whether nonstop running is normal for the cold or comes from a setting, a dirty filter or a blocked outdoor unit.

Short answer: In very cold weather, running nonstop is normal; otherwise a big thermostat setback, a dirty filter or a blocked or iced outdoor unit is likely. Check the thermostat, replace the filter and clear around the outdoor unit without chipping ice. If thick ice stays or aux heat runs above 40°F, call an HVAC technician.
Check the warning signs below first.
Use this guide at your own risk. It’s general information, not professional advice. By using it, you agree to our Terms of Use and Safety Waiver.
Check for danger first
If any of these are present, stop here.
- Gas odor, smoke or fire. Leave immediately. From outside, call emergency services. For a gas odor, also call the gas utility. Leave lights and switches alone.
- Burning smell, scorch marks, a hot outlet or a buzzing panel. Stop and call an electrician. Stay clear of a suspect panel.
- Water near electrical equipment or exposed wiring. Keep away. Never cross water to reach a plug or breaker. Call a qualified electrician.
None of these warning signs? Open the checks
What to check
Have ready. A new air filter in the right size, a flashlight and the outdoor temperature.
Check the outdoor temperature.
In very cold weather it can be completely normal for a heat pump to run all the time. Aux heat coming on in the cold and during defrost is normal too. Nonstop running on a mild day points to a problem.
Check the thermostat.
Make sure it’s set to Heat, not Cool. Keep setbacks small: Trane says raising the setpoint more than 3 to 4 degrees at once can bring on aux heat, and Carrier says recovering from a big overnight setback often does too.
Replace a dirty filter.
A clogged filter makes the system run longer and heat less. Put in a new filter of the same size.
Look at the outdoor unit.
A thin layer of frost, under about 1/4 inch, is normal in winter, and a defrost cycle usually lasts about 5 to 10 minutes. Clear leaves, grass and snow so there’s about 24 inches of open space around it. Never chip or scrape ice off the unit.
When to stop. If thick ice stays after a defrost cycle, aux heat stays on when it’s above 40°F, or the house won’t warm up, turn the system off and call an HVAC technician. Use emergency heat only in a true emergency, and call for service right away if you do. Defrost parts, refrigerant and reversing valves are pro work.
What it costs
- The checks above: free.
- Pro heat pump repair: $150–$650, about $400 on average.
- Common fixes: a refrigerant recharge, $100–$600; a new reversing valve, $350–$700.
- Heat pump repair, national average range: $164–$722.
National US ranges from 2025–2026 cost guides: Fixr · Thumbtack. Prices in your area may differ.
Common causes
- Very cold weather. In extreme cold a heat pump can run all the time to keep up, and that’s normal. You can check
- Big thermostat setback or jump. Recovering from a large setback or raising the setpoint several degrees at once calls for longer runs and aux heat. You can check
- Dirty air filter. A clogged filter makes the system run longer and less effectively. You can check
- Outdoor unit blocked by snow or debris. Leaves, grass and snow around the unit cut the airflow it needs to heat. You can check
- Defrost problem or dirty outdoor coil. Thick ice that won’t clear in defrost, or a very dirty coil, keeps the system from keeping up. Call a pro
- Low refrigerant or failing reversing valve. Low refrigerant can’t make enough heat, and a bad reversing valve can keep it running constantly. Call a pro
Sources: Carrier · Carrier aux heat · Trane.
Further reading · Carrier
Still stuck? Get help with your exact problem.
Snap a photo and tell the app what you’ve tried. It walks you through your model, one safe step at a time, and tells you when to call a pro. Your first fix in the app is free.
The app is coming soon. Get one email the day it launches.
One email when the app launches. No spam. Privacy Policy