Furnace blowing cold air

Check the thermostat’s fan setting, the warm-up delay, the filter and vents, and the fuel and pilot before you call for service.

A sheer curtain billows above a heating register set into a wood floor.

Short answer: Most often the thermostat fan is set to On instead of Auto, the furnace is still warming up, or a dirty filter made it overheat. Set the fan to Auto, give it a minute, replace the filter and check the fuel and pilot. If it still blows cold, call an HVAC technician; ignition, flame sensor and condensate drain problems are pro work.

Check the warning signs below first.

Use this guide at your own risk. It’s general information, not professional advice. By using it, you agree to our Terms of Use and Safety Waiver.

Check for danger first

If any of these are present, stop here.

None of these warning signs? Open the checks

What to check

Have ready. Fresh thermostat batteries if it uses them, a new filter in the right size and a flashlight.

  1. Set the thermostat to Heat and the fan to Auto.

    With the fan set to On, the blower runs even when the furnace isn’t heating, so it blows cool air between cycles. Switch it to Auto, set the mode to Heat and the temperature above the room, and replace dead batteries.

  2. Give it a minute to warm up.

    Many furnaces wait about 30 to 60 seconds after the burners light before the blower starts, and the first air can feel cool. Your owner’s manual may list your model’s blower delay.

  3. Replace the filter and open the vents.

    A dirty filter can make the furnace overheat and shut the burners off as a safety measure while the blower keeps running. Turn the furnace off at the thermostat, put in a new filter, open the supply vents and clear the returns.

  4. Check the fuel and the pilot.

    Make sure other gas appliances work, or that the propane or oil tank isn’t empty. On an older furnace with a standing pilot, relight it only by following the lighting instructions on the furnace label. Newer furnaces with electronic ignition need a technician.

When to stop. If it still blows cold, the burners light and then go out, or the pilot won’t stay lit, stop and call an HVAC technician. Igniters, flame sensors, limit switches and the condensate drain on high-efficiency furnaces are pro work. If you smell gas, leave and call the gas utility from outside. If a CO alarm goes off, get everyone outside and call 911.

What it costs

National US ranges from 2025–2026 cost guides: Fixr · Thumbtack. Prices in your area may differ.

Common causes

  1. Fan set to On. The blower runs even when the burners are off, so it pushes unheated air between cycles. You can check
  2. Normal warm-up delay. The blower can start 30 to 60 seconds after the burners while the heat exchanger warms up. You can check
  3. Dirty filter. Restricted airflow makes the furnace overheat, and a limit switch shuts the burners off while the blower keeps running. You can check
  4. Pilot, igniter or flame sensor. If the pilot is out or the igniter or flame sensor fails, the burners don’t light or stay lit, and the blower moves cold air. Call a pro
  5. Clogged condensate drain. On high-efficiency furnaces, a clogged drain line trips a safety that keeps the burners from lighting. Call a pro
  6. Gas valve or control board. A stuck gas valve or a failed control board needs a technician. Call a pro

Sources: Carrier · Trane.

Further reading · Carrier